OnlineNursingOwl
← All nursing posts

Chemistry · Studypool

Calculate the exposure concentration Advanced Industrial Hygiene

Overview

The sampling results for the chemical hazards you tested for Acme Automotive Parts (AAP) are listed in the following table. The volumes that are listed are what you provided to the laboratory.

Hazard

Analytical Result

Volume (Time)

Manganese Fume

5 µg

30 L (15-minute)

Copper Fume

140 µg

960 L (8-hour)

Lead Fume

40 µg

960 L (8-hour)

1,2,4 trimethylbenzene

5 µg

48 L (8-hour)

Toluene

125 µg

48 L (8-hour)

Xylene

20 µg

48 L (8-hour)

Metal Working Fluids

500 µg

720 L (8-hour)

For each of the chemical hazards in the table, complete the following:

  • Calculate the exposure concentration in mg/m3 for the aerosols.
  • Calculate the exposure in parts per million (ppm) for the vapors.
  • Discuss where you think errors might have been introduced into the results.
  • Compare your calculated exposures to one of the occupational exposure limits (OELs) in the table below.
  • Do any of the calculated exposures exceed the OEL you chose?
  • Discuss why you chose the OELs you used.
  • Provide your opinion as to whether the risk associated with each exposure is an acceptable level of risk.

Hazard

Occupational Exposure Limits (OEL)s

Manganese Fume

5 mg/m3 (OSHA Ceiling )

0.1 mg/m3 (ACGIH 8-hour TWA (I))

Copper Fume

0.1 mg/m3 (OSHA 8-hour TWA)

0.2 mg/m3 (ACGIH 8-hour TWA)

Lead Fume

0.05 mg/m3 (OSHA 8-hour TWA)

0.05 mg/m3 (ACGIH 8-hour TWA

1,2,4 trimethylbenzene

OSHA – None Established

25 ppm (ACGIH 8-hour TWA TLV)

Toluene

200 ppm (OSHA 8-hour TWA)

300 ppm (OSHA Ceiling)

20 ppm (ACGIH 8-hour TWA TLV)

Xylene

100 ppm (OSHA 8-hour TWA)

100 ppm (ACGIH 8-hour TWA

Metal Working Fluids

OSHA – None Established

0.5 mg/m3 (NIOSH 10-hour TWA REL)

The results for the noise sampling in the following table were recorded from your noise dosimeters. All the samples were collected for the full shift using 90 decibels on the A scale (dBA) as the criterion level and a 5 decibels (dB) exchange rate.

Location

Shift Length

Result

Shipping/Receiving

8 hours

78.3 dBA (Lavg)

Hydraulic Press

12 hours

93.0 dBA (Lavg)

Metal Working Line

12 hours

84 dBA (Lavg)

Robotic Welding

12 hours

80.5 dBA (Lavg)

Hand Welding

12 hours

81.3 dBA (Lavg)

Paint Booth

12 hours

79.5 dBA (Lavg)

QA/QC Laboratory

8 hours

70.0 dBA (Lavg)

Final Inspection

8 hours

73.5 dBA (Lavg)

Answer the following for each of the locations listed above:

  • Convert the results from dBA to percent. Make sure you show all your work for calculations.
  • Which of the results exceeds the OSHA PEL?
  • Which of the results exceeds the OSHA action level?
  • Provide your opinion as to whether the risk associated with each exposure is an acceptable level of risk.

Your assignment must be at least three pages in length, not counting the title or reference pages. Your assignment must use at least two references. One must be gathered from the CSU Online Library; the other may be your textbook. All references and in-text citations must be formatted according to APA Style.

Below is a YouTube video